Bug
-
Resolution: Done
-
Blocker
-
None
-
AMQ 7.10.1.OPR.1.GA
-
None
see https://issues.redhat.com/browse/ENTMQBR-7379
Acceptor/Connector service is not included in the fix for ENTMQBR-7379 so creating a seprarate issue for it.
1) Create Operator 7.10
2) Install broker w/ acceptor/connector enabled (default CR from examples would suffice)
3) Upgrade broker to 7.10.2
4) Observe error about Acceptor/Connector services.
5) Send messages through AMQP Service
6) See timeouts.
Those services are not (re) created and are not taken over by the newly installed operator, so they are left as a sort of "residue" after custom resource removal.
- is caused by
-
ENTMQBR-7402 7.10.0 operator doesn't set owner reference in AMQP Connector/Acceptor resources
- Closed
- is cloned by
-
ENTMQBR-7401 [LTS] [Operator, upgrade] the upgrade to 7.10.1 fails to create new Acceptor/Connector *v1.Service
- Closed
- is related to
-
ENTMQBR-7111 [Operator, upgrade] 7.10 versions of operator tend to remove stateful set during upgrade
- Closed