Bug
-
Resolution: Done
-
Blocker
-
AMQ 7.4.0.GA
-
None
-
None
We have following scenario:
- 2 EAP instances (nodeA, nodeB)
- nodeB has a MDB deployed, that consumes messages from an InQueue on nodeA and resends them to an OutQueue also on nodeA
- during the MDB processing of messages, nodeA is killed (actually killed, not a clean shutdown)
After that nodeB hangs when trying to shut it down and has to be killed.
This is a regression against 7.2.3.CR2 with Artemis 2.7.0.redhat-00057
- blocks
-
JBEAP-17062 [GSS](7.2.z) Upgrade Artemis from 2.7.0.redhat-00057 to 2.9.0.redhat-00005
- Closed
- clones
-
JBEAP-17323 [QA](7.2.z) Shutdown of server with remote JCA MDB hangs
- Closed
- is duplicated by
-
ENTMQBR-3071 Increased time gap in failover with MQ 7.5 client runtime
- Closed
- relates to
-
ENTMQBR-2719 Lost messages in scenario with a remote MDB and a long GC pause.
- Closed