Is RHCL fully supported when deployed on a bare metal OCP cluster?

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Duplicate
    • Icon: Critical Critical
    • None
    • 1.2.1
    • Documentation
    • False
    • Hide

      None

      Show
      None
    • False

      Current behaviour

      When deploying RHCL on a bare metal OCP cluster an error is encountered where the Gateway remains in an "unknown" status.

      Workarounds such as modifying the connected service with type=nodePort instead of type=loadBalancer is unsupported as already discussed in CONNLINK-515 but the documentation does not specify any prerequisites that suggest a bare metal OCP cluster would not work.

      Expected behaviour

      If RHCL has some prerequisites such as an LB for example then it should be listed especially if the environments where it is tested comes with an LB preinstalled because some deployment options of OCP like bare metal do not come with an LB out-of-the-box and therefore it must be configured with MetalLB.

      Also, it should be stated whether any LB can be used or if we make no recommendations and whatever is supported by OCP is supported by RHCL.