Bug
-
Resolution: Unresolved
-
Normal
-
CNV v4.18.3
-
None
-
Quality / Stability / Reliability
-
0.42
-
False
-
-
False
-
CNV v4.99.0.rhel9-2331
-
-
CNV I/U Operators Sprint 272, CNV I/U Operators Sprint 273, CNV I/U Operators Sprint 274, CNV I/U Operators Sprint 275, CNV I/U Operators Sprint 276, CNV I/U Operators Sprint 277, CNV I/U Operators Sprint 278
-
None
Description of problem:
NodeNetworkInterfaceDown alert firing for unused nic without the link
Version-Release number of selected component (if applicable):
kubevirt-hyperconverged-operator.v4.18.3
How reproducible:
everytime
Steps to Reproduce:
1. install ocp 4.17 with virtualization operator 2. attach unused interfaces to the worker 3. upgrade to ocp 4.18 or 1, attach new interface to the node do not attach cable to the interface 2, reboot the baremetalhost
Actual results:
false positive alert for unconfigured interfaces
Expected results:
unconfigured interfaces will be ignored
Additional info: