Bug
-
Resolution: Unresolved
-
Major
-
None
-
None
-
0.42
-
False
-
-
False
-
None
-
---
-
---
-
-
None
Description of problem: Seen multiple times against 4.18 network T2 gating lanes, causes T2 gating tests to fail.
e.g.: https://main-jenkins-csb-cnvqe.apps.ocp-c1.prod.psi.redhat.com/job/test-pytest-cnv-4.18-network-gating/50/ - 3 tests https://main-jenkins-csb-cnvqe.apps.ocp-c1.prod.psi.redhat.com/job/test-pytest-cnv-4.18-network-gating/40/testReport/ - 3 tests
Version-Release number of selected component (if applicable):
v4.18.0.rhel9-397 and v4.18.0.rhel9-351
How reproducible:
Intermittently - seen twice in last one week
Steps to Reproduce:
1. Create vms for network tests 2. 3.
Actual results:
Expected results:
Additional info:
Vms for these tests were created, and in the events collected I see they initially failed scheduling:
0/6 nodes are available: 1 Insufficient bridge.network.kubevirt.io/br6test, 2 node(s) didn't match Pod's node affinity/selector, 3 node(s) had untolerated taint {node-role.kubernetes.io/master: }. preemption: 0/6 nodes are available: 1 No preemption victims found for incoming pod, 5 Preemption is not helpful for scheduling.
Then I see SyncFailed event with message "failed to configure vmi network: setup failed, err: Critical network error: failed to setup link [k6t-d9ccdbb6cf3]: interrupted system call"
Subsequently a "The VirtualMachineInstance crashed." event message is seen before a "Killing" event with message "Stopping container compute" is seen. After that I see the vm was successfully created. These sequence of events are causing gating tests to fail (as we catch the vm in "Failed" status and assume it is not recoverable.
Will attach collected must-gather