Uploaded image for project: 'OpenShift Virtualization'
  1. OpenShift Virtualization
  2. CNV-31572

[2227957] tekton pipelines leftovers after successful runs

XMLWordPrintable

    • Important
    • No

      Description of problem:
      For successful pipelines and cleanup jobs being run , there are pvc leftovers in bound and terminating states.

      $ oc get prs -A
      NAMESPACE NAME SUCCEEDED REASON STARTTIME COMPLETIONTIME
      openshift-cnv windows-efi-installer-96esji True Succeeded 6h30m 6h12m

      Leftovers:

      $ oc get pvc -A | grep win11-ns1
      openshift-cnv win11-ns1-5sj9j Terminating pvc-17e7f059-d87c-4797-91cd-3f823798a4d4 329Gi RWO hostpath-csi-basic 6h33m
      test-tekton-03 win11-ns1 Bound pvc-09e836a2-7ba7-44e3-8e4e-8e3d713afb40 329Gi RWO hostpath-csi-basic 6h18m
      $ oc get pvc -A | grep windows-efi-root-disk-c7wgb
      openshift-cnv windows-efi-root-disk-c7wgb Bound pvc-b4dbab38-67a2-4c4e-b8a3-5468a66d641e 329Gi RWO hostpath-csi-basic 6h16m

      2. Logs of cleanup pods are mostly empty and didn't describe any action data for user's reference.

      Version-Release number of selected component (if applicable):
      4.14

      How reproducible:
      always (ran twice)

      Steps to Reproduce:
      1. yaml attached that can be used to reproduce
      2.
      3.

      Actual results:

      cleanup is not as expected

      Expected results:

      Additional info: