Uploaded image for project: 'Application Server 7'
  1. Application Server 7
  2. AS7-2630

Cannot configure a HornetQ connector pointing at a remote server

    XMLWordPrintable

Details

    • Bug
    • Resolution: Done
    • Critical
    • 7.1.0.Beta1
    • 7.0.2.Final
    • JMS
    • None

    Description

      The HQ subsystem connector element takes a socket-binding reference, and socket bindings are designed for local server sockets. As part of setting up the SocketBinding service the interface has to successfully resolve against one of the interfaces on the local machine. The effect is the connector configuration cannot point to a remote server.

      Solution is to support having the socket binding point to the outgoing-socket-binding Jaikiran Pai recently added.

      Attachments

        Activity

          People

            bstansbe@redhat.com Brian Stansberry
            bstansbe@redhat.com Brian Stansberry
            Votes:
            0 Vote for this issue
            Watchers:
            1 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: