[root@edpm-compute-0 openvswitch]# cat ovs-vswitchd.log 2024-08-04T00:00:01.144Z|00068|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2024-08-04T11:05:30.626Z|00069|bridge|INFO|bridge br-ex: deleted interface vlan396 on port 6 2024-08-04T11:05:30.626Z|00070|bridge|INFO|bridge br-ex: deleted interface br-ex on port 65534 2024-08-04T11:05:30.626Z|00071|bond|INFO|member ens1f1: disabled 2024-08-04T11:05:30.626Z|00072|bond|INFO|bond bond0: active member is now ens1f0 2024-08-04T11:05:30.626Z|00073|bond|INFO|member ens1f0: disabled 2024-08-04T11:05:30.626Z|00074|bond|INFO|bond bond0: all members disabled 2024-08-04T11:05:30.626Z|00075|bridge|INFO|bridge br-ex: deleted interface ens1f1 on port 1 2024-08-04T11:05:30.626Z|00076|bridge|INFO|bridge br-ex: deleted interface ens1f0 on port 2 2024-08-04T11:05:30.626Z|00077|bridge|INFO|bridge br-ex: deleted interface vlan395 on port 5 2024-08-04T11:05:30.626Z|00078|bridge|INFO|bridge br-ex: deleted interface vlan391 on port 3 2024-08-04T11:05:30.626Z|00079|bridge|INFO|bridge br-ex: deleted interface vlan394 on port 4 2024-08-04T11:05:30.627Z|00080|bridge|INFO|bridge br-int: deleted interface ovn-31df4a-0 on port 1 2024-08-04T11:05:30.627Z|00081|bridge|INFO|bridge br-int: deleted interface ovn-723ca0-0 on port 3 2024-08-04T11:05:30.627Z|00082|bridge|INFO|bridge br-int: deleted interface ovn-735b77-0 on port 2 2024-08-04T11:05:30.627Z|00083|bridge|INFO|bridge br-int: deleted interface br-int on port 65534 2024-08-04T11:05:31.048Z|00001|vlog|INFO|opened log file /var/log/openvswitch/ovs-vswitchd.log 2024-08-04T11:05:31.076Z|00002|ovs_numa|INFO|Discovered 64 CPU cores on NUMA node 1 2024-08-04T11:05:31.076Z|00003|ovs_numa|INFO|Discovered 64 CPU cores on NUMA node 0 2024-08-04T11:05:31.076Z|00004|ovs_numa|INFO|Discovered 2 NUMA nodes and 128 CPU cores 2024-08-04T11:05:31.076Z|00005|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connecting... 2024-08-04T11:05:31.076Z|00006|reconnect|INFO|unix:/var/run/openvswitch/db.sock: connected 2024-08-04T11:05:31.077Z|00007|dpdk|INFO|DPDK Disabled - Use other_config:dpdk-init to enable 2024-08-04T11:05:31.079Z|00008|ofproto_dpif|INFO|system@ovs-system: Datapath supports recirculation 2024-08-04T11:05:31.079Z|00009|ofproto_dpif|INFO|system@ovs-system: VLAN header stack length probed as 2 2024-08-04T11:05:31.079Z|00010|ofproto_dpif|INFO|system@ovs-system: MPLS label stack length probed as 3 2024-08-04T11:05:31.079Z|00011|ofproto_dpif|INFO|system@ovs-system: Datapath supports truncate action 2024-08-04T11:05:31.080Z|00012|ofproto_dpif|INFO|system@ovs-system: Datapath supports unique flow ids 2024-08-04T11:05:31.080Z|00013|ofproto_dpif|INFO|system@ovs-system: Datapath supports clone action 2024-08-04T11:05:31.080Z|00014|ofproto_dpif|INFO|system@ovs-system: Max sample nesting level probed as 10 2024-08-04T11:05:31.080Z|00015|ofproto_dpif|INFO|system@ovs-system: Datapath supports eventmask in conntrack action 2024-08-04T11:05:31.080Z|00016|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_clear action 2024-08-04T11:05:31.080Z|00017|ofproto_dpif|INFO|system@ovs-system: Max dp_hash algorithm probed to be 1 2024-08-04T11:05:31.080Z|00018|ofproto_dpif|INFO|system@ovs-system: Datapath supports check_pkt_len action 2024-08-04T11:05:31.080Z|00019|ofproto_dpif|INFO|system@ovs-system: Datapath supports timeout policy in conntrack action 2024-08-04T11:05:31.080Z|00020|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zero_snat 2024-08-04T11:05:31.080Z|00021|ofproto_dpif|INFO|system@ovs-system: Datapath supports add_mpls action 2024-08-04T11:05:31.080Z|00022|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state 2024-08-04T11:05:31.080Z|00023|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_zone 2024-08-04T11:05:31.080Z|00024|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_mark 2024-08-04T11:05:31.080Z|00025|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_label 2024-08-04T11:05:31.080Z|00026|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_state_nat 2024-08-04T11:05:31.080Z|00027|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple 2024-08-04T11:05:31.080Z|00028|ofproto_dpif|INFO|system@ovs-system: Datapath supports ct_orig_tuple6 2024-08-04T11:05:31.080Z|00029|ofproto_dpif|INFO|system@ovs-system: Datapath does not support IPv6 ND Extensions 2024-08-04T11:05:31.081Z|00030|ofproto_dpif_upcall|INFO|Overriding n-handler-threads to 128, setting n-revalidator-threads to 33 2024-08-04T11:05:31.081Z|00031|ofproto_dpif_upcall|INFO|Starting 161 threads 2024-08-04T11:05:31.111Z|00001|ofproto_dpif_upcall(handler5)|INFO|received packet on unassociated datapath port 4 (no OpenFlow port for datapath port 4) 2024-08-04T11:05:31.112Z|00001|ofproto_dpif_upcall(handler33)|INFO|received packet on unassociated datapath port 5 (no OpenFlow port for datapath port 5) 2024-08-04T11:05:31.128Z|00001|ofproto_dpif_upcall(handler16)|INFO|received packet on unassociated datapath port 4 (no OpenFlow port for datapath port 4) 2024-08-04T11:05:31.128Z|00001|ofproto_dpif_upcall(handler26)|INFO|received packet on unassociated datapath port 5 (no OpenFlow port for datapath port 5) 2024-08-04T11:05:31.166Z|00032|bridge|INFO|bridge br-ex: added interface ens1f1 on port 1 2024-08-04T11:05:31.166Z|00033|bridge|INFO|bridge br-ex: added interface ens1f0 on port 2 2024-08-04T11:05:31.166Z|00034|bridge|INFO|bridge br-ex: added interface br-ex on port 65534 2024-08-04T11:05:31.166Z|00035|bridge|INFO|bridge br-ex: added interface vlan396 on port 6 2024-08-04T11:05:31.166Z|00036|bridge|INFO|bridge br-ex: added interface vlan391 on port 3 2024-08-04T11:05:31.166Z|00037|bridge|INFO|bridge br-ex: added interface vlan395 on port 5 2024-08-04T11:05:31.166Z|00038|bridge|INFO|bridge br-ex: added interface vlan394 on port 4 2024-08-04T11:05:31.166Z|00039|bridge|INFO|bridge br-int: added interface ovn-31df4a-0 on port 1 2024-08-04T11:05:31.166Z|00040|bridge|INFO|bridge br-int: added interface ovn-735b77-0 on port 2 2024-08-04T11:05:31.166Z|00041|bridge|INFO|bridge br-int: added interface ovn-723ca0-0 on port 3 2024-08-04T11:05:31.166Z|00042|bridge|INFO|bridge br-int: added interface br-int on port 65534 2024-08-04T11:05:31.166Z|00043|bridge|INFO|bridge br-ex: using datapath ID 0000303ea700a404 2024-08-04T11:05:31.166Z|00044|bond|INFO|member ens1f1: enabled 2024-08-04T11:05:31.166Z|00045|bond|INFO|member ens1f0: enabled 2024-08-04T11:05:31.167Z|00046|connmgr|INFO|br-ex: added service controller "punix:/var/run/openvswitch/br-ex.mgmt" 2024-08-04T11:05:31.167Z|00047|bridge|INFO|bridge br-int: using datapath ID 0000e63ab7ca100e 2024-08-04T11:05:31.167Z|00048|connmgr|INFO|br-int: added service controller "punix:/var/run/openvswitch/br-int.mgmt" 2024-08-04T11:05:31.167Z|00049|bond|INFO|bond bond0: active member is now ens1f1 2024-08-04T11:05:31.170Z|00050|bridge|INFO|ovs-vswitchd (Open vSwitch) 3.2.3 2024-08-04T11:05:41.173Z|00051|memory|INFO|492696 kB peak resident set size after 10.1 seconds 2024-08-04T11:05:41.173Z|00052|memory|INFO|handlers:128 idl-cells-Open_vSwitch:678 ofconns:4 ports:11 revalidators:33 rules:29 udpif keys:145 2024-08-04T11:05:50.801Z|00053|connmgr|INFO|br-int<->unix#3: 21 flow_mods 10 s ago (20 adds, 1 deletes)