      Description

      If the VIP is not on ens192, the VIP is inaccessible from outside the machine network. This seems to be due to ens192 having the first default route in the routing table. When that route is deleted, the VIP becomes accessible.

      Acceptance Criteria

      • In CI, restrict VIP to machine network on 1st adapter in the topology
      • Create a task to update docs with this requirement

      created from thread: https://redhat-internal.slack.com/archives/G012C6LKVM2/p1725480256979079