Bug
-
Resolution: Done
-
Undefined
-
None
-
4.12.0
-
Critical
-
None
-
Rejected
-
False
-
-
This is a clone of issue OCPBUGS-5377. The following is the description of the original issue:
—
Description of problem:
Multiple times switching slave port to fault causes the port state to remain in HOLDOVER and fails to move to FREERUN
Version-Release number of selected component (if applicable):
12
How reproducible:
ip link set ens4f0 down for slave port
Steps to Reproduce:
1. 2. 3.
Actual results:
Stays in HOLDOVER metrics and events
Expected results:
Should move to FREERUN after TimeOut
Additional info:
- blocks
-
OCPBUGS-5555 Multiple times switching slave port to fault causes the port state to remain in HOLDOVER
- Closed
- clones
-
OCPBUGS-5377 Multiple times switching slave port to fault causes the port state to remain in HOLDOVER
- Closed
- is blocked by
-
OCPBUGS-5377 Multiple times switching slave port to fault causes the port state to remain in HOLDOVER
- Closed
- is cloned by
-
OCPBUGS-5555 Multiple times switching slave port to fault causes the port state to remain in HOLDOVER
- Closed