Uploaded image for project: 'OpenShift Bugs'
  1. OpenShift Bugs
  2. OCPBUGS-10689

[IPI on BareMetal]: Workers failing inspection when installing with proxy

    XMLWordPrintable

Details

    • Important
    • No
    • Rejected
    • False
    • Hide

      Not a release blocker, pre-existing problem

      Show
      Not a release blocker, pre-existing problem

    Description

      This is a clone of issue OCPBUGS-5461. The following is the description of the original issue:

      Description of problem:

      When installing a 3 master + 2 worker BM IPv6 cluster with proxy, worker BMHs are failing inspection with the message: "Could not contact ironic-inspector for version discovery: Unable to find a version discovery document". This causes the installation to fail due to nodes with worker role never joining the cluster. However, when installing with no workers, the issue does not reproduce and the cluster installs successfully.

      Version-Release number of selected component (if applicable):

      4.12.0-0.nightly-2023-01-04-203333

      How reproducible:

      100%

      Steps to Reproduce:

      1. Attempt to install an IPv6 cluster with 3 masters + 2 workers and proxy with baremetal installer
      

      Actual results:

      Installation never completes because a number of pods are in Pending status

      Expected results:

      Workers join the cluster and installation succeeds 

      Additional info:

      $ oc get events
      LAST SEEN   TYPE     REASON              OBJECT                               MESSAGE
      174m        Normal   InspectionError     baremetalhost/openshift-worker-0-1   Failed to inspect hardware. Reason: unable to start inspection: Could not contact ironic-inspector for version discovery: Unable to find a version discovery document at https://[fd2e:6f44:5dd8::37]:5050, the service is unavailable or misconfigured. Required version range (any - any), version hack disabled.
      174m        Normal   InspectionError     baremetalhost/openshift-worker-0-0   Failed to inspect hardware. Reason: unable to start inspection: Could not contact ironic-inspector for version discovery: Unable to find a version discovery document at https://[fd2e:6f44:5dd8::37]:5050, the service is unavailable or misconfigured. Required version range (any - any), version hack disabled.
      174m        Normal   InspectionStarted   baremetalhost/openshift-worker-0-0   Hardware inspection started
      174m        Normal   InspectionStarted   baremetalhost/openshift-worker-0-1   Hardware inspection started
      

      Attachments

        Issue Links

          Activity

            People

              dhiggins@redhat.com Derek Higgins
              openshift-crt-jira-prow OpenShift Prow Bot
              Trey West Trey West
              Votes:
              0 Vote for this issue
              Watchers:
              9 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: