Uploaded image for project: 'OpenShift Logging'
  1. OpenShift Logging
  2. LOG-1735

Regression introducing flush_at_shutdown

    XMLWordPrintable

Details

    • False
    • False
    • NEW
    • NEW
    • Hide
      Before this update, a regression introduced in a prior release configuration caused the collector to flush its buffered messages before shutdown, creating a delay the termination and restart of collector Pods. With this update, fluentd no longer flushes buffers at shutdown, resolving the issue.
      Show
      Before this update, a regression introduced in a prior release configuration caused the collector to flush its buffered messages before shutdown, creating a delay the termination and restart of collector Pods. With this update, fluentd no longer flushes buffers at shutdown, resolving the issue.
    • Logging (Core) - Sprint 207

    Description

      Flushing at shutdown of fluentd contributes to the slow nature in the collector pod terminating. This change was introduced as part of:
      https://github.com/openshift/cluster-logging-operator/commit/84acb5929d363aa0506d87fe24cd52a3e4c569b6

      which AFAIK was unintentional as it was

      Attachments

        Activity

          People

            jcantril@redhat.com Jeffrey Cantrill
            jcantril@redhat.com Jeffrey Cantrill
            Anping Li Anping Li
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: